SR-380 Spectroradiometer Characteristic

  • It has the characteristics of high dynamic range, high speed and high precision.
  • It can measure luminance as low as 0.01cd/m2 and high luminance up to about 1,200,000cdm2.
  • Comply with IEC62471, IEC62778, GB7000.1 and other optical radiation safety test requirements.
  • Realize the measurement of photobiological safety parameters such as high-speed, high-precision luminance, chrominance, radiance, and retinal blue light hazard-weighted radiance.
  • The 4.3-inch touch screen can set various parameters by touch and read the measurement data directly.
  • Three electrically switchable measuring angles are 100mrad, 11mrad, 1.7mrad.
  • It can visually display spectral distribution map, CIE chromaticity chart, etc.
  • Optional flicker measurement function.

SR-380 Spectroradiometer Application

•FPD optical characteristics measurement analysis
•Micro LED, Mini LED optical analysis
•Backlight module luminance, chrominance analysis
•Luminous character luminance analysis
•Automobile instrument panel chrominance analysis
•Interior atmosphere optical analysis
•Center control screen chrominance analysis
•Various light sources radiometric measurement

SR-380 Spectroradiometer Specification

Model

SR-380

Wavelength Range

200-850nm

Wavelength Accuracy

±0.3nm

Spectral Wavelength Width

5nm or less (half-wave width)

Aperture Diaphragm

7mm

Measurement Angle

100mrad、11mrad、1.7mrad

Min Measurement Display

0.0001cd/m2

Min Spectral Radiance Display

10-9W(sr.m2.nm)

Measurement Function

Spectrum, radiant luminance, luminance, CIE chromaticity coordinates, color temperature, tristimulus value, dominant wavelength

Luminance Measurement Range

100mrad:0.01-20,000cd/m2

11mrad:0.075-100,000cd/m2

1.7mrad:3-1,200,000cd/m2

Luminance Accuracy

±2% @Illuminant A

Chrominance Accuracy

x,y :±0.002

Luminance Repeatability

1% @Illuminant A(0.1-5cd/m2)

0.5% @Illuminant A(>5cd/m2)

Chrominance Repeatability

0.005 @Illuminant A(0.1-5cd/m2)

0.002 @Illuminant A(>5cd/m2)

Switch Measurement Angle

Electrodynamic

Operation Temperature

5-50°

Interface

LAN, RS-232

Dimension

260*170*190 (Length, Width and Height)

Power Supply

AC power adapter

*Measurement of luminance and chrominance is based on RayClouds conditions (using 1000cd/m2 standard light source, LED backlight, 6500K LCD display).

*Specifications and appearance are subject to change without prior notice.