Model |
V-20M |
V-26M |
V-46M |
V-61M |
V-150M |
|
Total Pixel (million) |
20 |
26 |
46 |
61 |
150 |
|
Cooled System |
Two stage TEC.(Typical -45 below Ambient) |
|||||
Measurement Function |
Luminance |
|||||
Luminance |
Measurement Range |
0.001 to 100,000cd/m2 (Using ND can be higher) |
||||
Accuracy*¹ |
±3% |
|||||
Repeatability(δ)*¹ |
±0.5% |
|||||
Lens |
A-50(50 degrees diagonal)| A-70(70 degrees diagonal) A-100(100 degrees diagonal)| A-120(120 degrees diagonal) |
*Measurement of luminance and chrominance measurement is based on RayClouds conditions (using 500cd/m2 standard light source, LED backlight, 6500K LCD display).
*Repeatability measurement conditions @ using a luminance 500cd/m2 standard light source, taking the average of 100 pixels in the center.
*Specifications and appearance are subject to change without prior notice.
Model |
V-20S |
V-26S |
V-46S |
V-61S |
Total Pixel (million) |
20 |
26 |
46 |
61 |
Cooled System |
Two stage TEC.(Typical -45 below Ambient) |
|||
Measurement Function |
Luminance, CIE chromaticity coordinates, CCT, Dominant wavelength, Tristimulus value |
|||
Luminance |
Measurement Range |
0.0001 to 100,000cd/m2(Using ND can be higher) |
||
Accuracy*¹ |
±3% |
|||
Repeatability(δ)*¹ |
±0.5% |
|||
Chrominance |
Illuminant A*¹ |
±0.002 |
||
Repeatability(δ)*¹ |
±0.0003 |
|||
Lens |
A-50(50 degrees diagonal)| A-70(70 degrees diagonal) A-100(100 degrees diagonal)| A-120(120 degrees diagonal) |
*Measurement of luminance and chrominance measurement is based on RayClouds conditions (using 500cd/m2 standard light source, LED backlight, 6500K LCD display).
*Repeatability measurement conditions @ using a luminance 500cd/m2 standard light source, taking the average of 100 pixels in the center.
*Specifications and appearance are subject to change without prior notice.
Model |
V-20F |
V-26F |
V-46F |
V-61F |
V-150F |
|
Total Pixel (million) |
20 |
26 |
46 |
61 |
150 |
|
Cooled System |
Two stage TEC.(Typical -45 below Ambient) |
|||||
Measurement Function |
Luminance, CIE chromaticity coordinates, CCT, Dominant wavelength, Tristimulus value |
|||||
Luminance |
Measurement Range |
0.0001 to 100,000cd/m2(Using ND can be higher) |
||||
Accuracy*¹ |
±3% |
|||||
Repeatability(δ)*¹ |
±0.5% |
|||||
Chrominance |
Illuminant A*¹ |
±0.002 |
||||
Repeatability(δ)*¹ |
±0.0003 |
|||||
Lens |
A-50(50 degrees diagonal)| A-70(70 degrees diagonal) A-100(100 degrees diagonal)| A-120(120 degrees diagonal) |
*Measurement of luminance and chrominance measurement is based on RayClouds conditions (using 500cd/m2 standard light source, LED backlight, 6500K LCD display).
*Repeatability measurement conditions @ using a luminance 500cd/m2standard light source, taking the average of 100 pixels in the center.
*Specifications and appearance are subject to change without prior notice.