There are Luminance type, Spectral type, Filter type designs, and optional multi angle lens. Equipped with detectors of multiple resolutions and a front aperture lens with a wide field of view, it provides an excellent solution for testing luminance and chromaticity. Even weak signals with luminance as low as 0.001cd/m ^ 2 can be reliably analyzed. Front aperture lens design, simulating eye pupil sizes of 3.6mm to 8mm for the human eye. 

V Series ARVR Imaging Colorimeter Luminance Type

Model

V-20M

V-26M

V-46M

V-61M

V-150M

Total Pixel (million)

20

26

46

61

150

Cooled System

Two stage TEC.(Typical -45 below Ambient)

Measurement Function

Luminance

Luminance

Measurement Range

0.001 to 100,000cd/m2 (Using ND can be higher)

Accuracy*¹

±3%

Repeatability(δ)*¹

±0.5%

Lens

A-50(50 degrees diagonal)| A-70(70 degrees diagonal)

A-100(100 degrees diagonal)| A-120(120 degrees diagonal)


*Measurement of luminance and chrominance measurement is based on RayClouds conditions (using 500cd/m2 standard light source, LED backlight, 6500K LCD display).

*Repeatability measurement conditions @ using a luminance 500cd/m2 standard light source, taking the average of 100 pixels in the center.

*Specifications and appearance are subject to change without prior notice.

V Series ARVR Imaging Colorimeter Spectral Type

Model

V-20S

V-26S

V-46S

V-61S

Total Pixel (million)

20

26

46

61

Cooled System

Two stage TEC.(Typical -45 below Ambient)

Measurement Function

Luminance, CIE chromaticity coordinates, CCT, Dominant wavelength, Tristimulus value

Luminance

Measurement Range

0.0001 to 100,000cd/m2(Using ND can be higher)

Accuracy*¹

±3%

Repeatability(δ)*¹

±0.5%

Chrominance

Illuminant A*¹

±0.002

Repeatability(δ)*¹

±0.0003

Lens

A-50(50 degrees diagonal)| A-70(70 degrees diagonal)

A-100(100 degrees diagonal)| A-120(120 degrees diagonal)


*Measurement of luminance and chrominance measurement is based on RayClouds conditions (using 500cd/m2 standard light source, LED backlight, 6500K LCD display).

*Repeatability measurement conditions @ using a luminance 500cd/m2 standard light source, taking the average of 100 pixels in the center.

*Specifications and appearance are subject to change without prior notice.

V Series ARVR Imaging Colorimeter Filter Type

Model

V-20F

V-26F

V-46F

V-61F

V-150F

Total Pixel (million)

20

26

46

61

150

Cooled System

Two stage TEC.(Typical -45 below Ambient)

Measurement Function

Luminance, CIE chromaticity coordinates, CCT, Dominant wavelength, Tristimulus value

Luminance

Measurement Range

0.0001 to 100,000cd/m2(Using ND can be higher)

Accuracy*¹

±3%

Repeatability(δ)*¹

±0.5%

Chrominance

Illuminant A*¹

±0.002

Repeatability(δ)*¹

±0.0003

Lens

A-50(50 degrees diagonal)| A-70(70 degrees diagonal)

A-100(100 degrees diagonal)| A-120(120 degrees diagonal)


*Measurement of luminance and chrominance measurement is based on RayClouds conditions (using 500cd/m2 standard light source, LED backlight, 6500K LCD display).

*Repeatability measurement conditions @ using a luminance 500cd/m2standard light source, taking the average of 100 pixels in the center.

*Specifications and appearance are subject to change without prior notice.